From inside (document excerpt):
The red strings club walkthrough. Product Data 58WAV WeatherMaker® 8000 Energy-Efficient Deluxe Upflow Furnace Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh Advanced Technology for Energy-Efficient Gas Furnaces Carrier leads the industry with its new WeatherMaker® 8000 InducedDraft Gas Furnace. This furnace is built with the most advanced manufacturing equipment, processes, and technology available in order to ensure top quality.
Carrier 58wav Troubleshooting
Shelter Furnace SF3042 Manuals & User Guides. User Manuals, Guides and Specifications for your Shelter Furnace SF3042 Furnace. Architecte 3d mac download software. Database contains 1 Shelter Furnace SF3042 Manuals (available for free online viewing or downloading in PDF): Manual. Carrier 58wav Service Manual Rating: 4,5/5 2531reviews Overview of 58WAV The Carrier 58WAV is a discontinued variable-speed gas-fired furnace with an efficiency of 80.0% AFUE. Carrier 58wav parts manual online Service and efficiency. Maintenance Instructions For the purchaser an efficiency rating of life. 58wav parts for Boost Mobile was written in between. The superior attention to the widest range of product leadership in between. GILERA 500 SERVICE REPAIR 2003 2004Online HVAC, DjVu, txt, DjVu forms.
Heating, Ventilating and Air Conditioning User Manual Free Download. HAVC Operator’s Manual. Gas Furnace and AC Free Instruction Manual Download PDF.
Packed into the cabinet are the industry’s foremost dealer and homeowner features. All models are GAMA efficiency rating certified and certified for use in California Air Quality Management Districts. These induced-combustion, gas-fired furnaces offer not only low installation costs, but fuel economy as well — delivering an Annual Fuel Utilization Efficiency (AFUE) rating of 80.0 percent. The Carrier WeatherMaker 8000 utilizes a hot surface, silicon carbide ignition system to save energy and increase reliability. Our design uses the patented S-shaped 4-pass heat exchanger, a soft mount inducer assembly, and a slow opening gas valve to improve sound level. The Super-S heat exchanger provides better heat transfer while enabling us to make a compact furnace. This provides more room in closet, utility room, and short basement installations. The heat exchanger is constructed of aluminized steel and is backed by a 20-year Limited Warranty. The Carrier WeatherMaker 8000 Gas Furnace will meet your home heating requirements. This furnace family provides the widest range of heating capacities available. The superior attention to cabinet detail is obvious. The Carrier WeatherMaker 8000 features 1-piece, 2000 Carrier Corporation Form No. 58WAV-9PD seamless, wrap-around construction. There are no spot welds on the exterior surfaces of the WeatherMaker 8000 Furnace. There is also double protection for the cabinet. First, a galvanized steel substrate provides resistance to rusting. Then the cabinet is constructed of prepainted steel–the same high-quality finish found on refrigerators and dishwashers. Perhaps the most advanced feature of the WeatherMaker 8000 is the microprocessor control board. The simplified electronics in this control board provide high reliability while performing many of the functions of older, electro-mechanical devices in other furnaces. Advanced features of the board show true leadership in furnace technology. The control board provides blower delay at start-up and shutdown, while monitoring furnace operations and functions. In the unlikely event of a service call, in less than a minute, the technician can use the self-test feature to determine if a major component has failed. The control board will check itself, then the inducer, silicon carbide ignition, low- and highspeed blower, and the humidifier connections. The control board also features a 3-amp fuse that protects the transformer and control board. Another feature on the control board is an LED status indicator light to ensure top furnace performance. Our induced-combustion furnace has a patented draft safeguard switch. The draft safeguard switch will stop furnace operation if the vent system becomes blocked or is not operating properly. Enhanced indoor air quality in your home is made easier with our media filter cabinet–a standard accessory on all deluxe upflow furnaces. When installed as a part of your system, this cabinet allows for easy and convenient addition of a Carrier high-efficiency air filter. Best of all, the Carrier WeatherMaker 8000 is made to be easily installed. Nexxt aulub155u2 usb drivers download. Many features make this furnace the easy choice for replacement or new construction markets.
Wikipedia’s page for Carrier
Carrier Company Web Site: www.corp.carrier.com
Categories | Carrier HVAC Manuals |
---|---|
Document Type | Heating, Ventilating and Air Conditioning Manual Free Download. HAVC Operator's Instruction Manual. |
Tags | Carrier 58WAV |
Download File | |
Language | English |
Product Brand | Carrier. Support Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays , Heating, Ventilating and Air Conditioning - HVAC |
Document File Type | |
Publisher | corp.carrier.com |
Wikipedia's Page | Carrier Corporation |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)
WeatherMaker 8000TM 58WAV Upflow Induced-Combustion Furnaces Visit www.carrier.com Installation, Start-Up, and Operating Instructions Sizes 045-155, Series 141 NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. Index Page SAFETY CONSIDERATIONS .1 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCEDURE 2-3 Dimensional Drawing .2 Clearances From Combustible Materials .3 INTRODUCTION .3 LOCATION 3 General .3 Location Relative to Cooling Equipment .3 Hazardous Locations .3 AIR FOR COMBUSTION AND VENTILATION 3-5 Unconfined Space 4 Confined Space 4-5 AIR DUCTS 5-6 General Requirements .5 Ductwork Acoustical Treatment 5-6 Supply-Air Connections 6 Return-Air Connections .6 FILTER ARRANGEMENT 5-6 LEVELING LEGS (IF REQUIRED) .5-6 GAS PIPING .6-7 ELECTRICAL CONNECTIONS .7 115-v Wiring 7 24-v Wiring 7 Accessories 7 VENTING .7 START-UP, ADJUSTMENT, AND SAFETY CHECK 7-14 General 7-8 Sequence Of Operation 8-11 Heating Mode .9-11 Cooling Mode 11 Continuous Blower Mode .11 Heat Pump Mode .11 Start-Up Procedures .11 Adjustments 11-14 Set Gas Input Rate .11-13 Set Temperature Rise .13-14 Set Thermostat Heat Anticipator 14 Check Safety Controls 14 Checklist 14 SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components. Core performance mark verstegen free download free.
Carrier 58wav Service Manual Transmission
Only trained and qualified personnel should install, repair, or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When working on ama CANADIAN GAS ASSOCIATION ® A PP R O VED R REGISTERED QUALITY SYSTEM heating equipment, observe precautions in the literature, on tags, and on labels attached to or shipped with the unit and other safety precautions that may apply. Follow all safety codes. In the United States, follow all safety codes including the National Fuel Gas Code (NFGC) NFPA 54-1996/ANSI Z223.1-1996 and the Installation Standards, Warm Air Heating and Air Conditioning Systems (NFPA 90B) ANSI/NFPA 90B. In Canada, refer to CAN/CGA-B149.1- and .2-M95 National Standard of Canada, Natural Gas and Propane Installation Codes (NSCNGPIC). These instructions cover minimum requirements and conform to existing national standards and safety codes. In some instances, these instructions exceed certain local codes and ordinances, especially those that may not have kept up with changing residential construction practices. We require these instructions as a minimum for a safe installation. Wear safety glasses and work gloves. Have fire extinguisher available during start-up and adjustment procedures and service calls. Recognize safety information. This is the safety-alert symbol. When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, CAUTION, and NOTE. These words are used with the safety-alert symbol. Myob serial number generator.